4. Check Refrigerant Pressure Sensor Ground Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between refrigerant pressure sensor terminal 3 and ECM terminal 67. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 6. CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT .
NG >> GO TO 5. DETECT MALFUNCTIONING PART .