5. Check PNP Switch Input Signal Circuit For Open And Short-II
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 102 and combination meter terminal 40. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7. CHECK INTERMITTENT INCIDENT .
NG >> GO TO 6. DETECT MALFUNCTIONING PART .