15. Check Stop Lamp Switch Input Signal Circuit For Open And Short
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 101 and stop lamp switch terminal 2.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK : GO TO 17 .
- NG : GO TO 16.