9. Check Condenser Ground Circuit
- Check harness continuity between condenser terminal 2 and ground. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to power.
OK or NG
- OK : GO TO 10.
- NG : Repair open circuit or short to power in harness or connectors.