3. Check Injector Power Supply Circuit
- Turn ignition switch OFF.
- Disconnect injector harness connector.
- Turn ignition switch ON.
- Check voltage between injector terminal 1 and ground with CONSULT-II or tester.
- Voltage: Battery voltage
OK or NG
- OK : GO TO 5 .
- NG : GO TO 4.