3. Check EGR Volume Control Valve Output Signal Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminals and EGR volume control valve terminals as follows.
Refer to WIRING DIAGRAM.
Fig 1: Check Harness Continuity Between ECM Terminals And EGR Volume Control Valve Terminals As FollowsCourtesy of NISSAN MOTOR CO., U.S.A.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 4.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.