Testing Condition:
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
With CONSULT-II
- Start engine and warm it up to normal operating temperature.
- Select "A/F SEN1 (B1)" or "A/F SEN1 (B2)" in "DATA MONITOR" mode with CONSULT-II.
- Check "A/F SEN1 (B1)" or "A/F SEN1 (B2)" indication.
If the indication is constantly approx. 1.5V and does not fluctuates, go to "DIAGNOSTIC PROCEDURE ".
If the indication fluctuates around 1.5V, go to next step.
- Select "A/F SEN1 (B1) P1276" or "A/F SEN1 (B2) P1286" of "A/F SEN1" in "DTC WORK SUPPORT" mode with CONSULT-II.
- Touch "START".
- When the following conditions are met, "TESTING" will be displayed on the CONSULT-II screen.
If "TESTING" is not displayed after 20 seconds, retry from step 2.
- Reidentifying accelerator pedal fully.NOTE: Never apply brake during releasing the accelerator pedal.
- Make sure that "TESTING" changes to "COMPLETED".
If "TESTING" changed to "OUT OF CONDITION, " retry from step 6.
- Make sure that "OK" is displayed after touching "SELF-DIAG RESULT".
If "NG" is displayed, go to "DIAGNOSTIC PROCEDURE ".