Home >> Nissan-Datsun >> 2004 >> Sentra SE-R Spec V >> Repair and Diagnosis >> External Pages >> Different car >> Section 1917 (Engine Control System (2AZ-FE)) >> SFI System >> DTC P2401 Evaporative Emission System Leak Detection Pump Control Circuit Low : DTC P2402 Evaporative Emission System Leak Detection Pump Control Circuit High >> Typical Enabling Conditions
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Enabling Conditions

WARNING: This page is about a different car, the 2006 Scion tC. However, it is still accessible from the selected car via links, so may be relevant.
TYPICAL ENABLING CONDITIONS

Monitor runs whenever these DTCs not present -
Atmospheric pressure (absolute pressure) 70 kPa (525 mmHg) or more, and less than 110 kPa (825 mmHg)
Battery voltage 10.5 V or more
Vehicle speed Below 4km/h (2.5 mph)
Ignition switch OFF
Soak time (ignition switch OFF time) 5, 7 or 9.5 hours
Engine coolant temperature 4.4 to 35°C (40 to 95°F)
Intake air temperature 4.4 to 35°C (40 to 95°F)
Canister pressure sensor malfunction (P0450, P0452, P0453) Not detected
Purge valve Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
When both conditions below are met: Condition 1 and 2 are met before key off
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed

Key-off monitor sequence 1 to 6 

1. Atmospheric pressure measurement 

ATMOSPHERIC PRESSURE MEASUREMENT

Next sequence is run if the following condition is met: -
Atmospheric change for 10 seconds Within 0.3 kPa (2.25 mmHg) in 1 second

2. First reference pressure measurement 

FIRST REFERENCE PRESSURE

Next sequence is run if the following conditions are met: -
EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or lower
Reference pressure -4.3 to -1.2 kPa (-32.2 to -90 mmHg)
Reference pressure Saturated within 60 seconds

3. Vent valve stuck closed check 

VENT VALVE STUCK CLOSED

Next sequence is run if following condition is met -
EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more

4. Vacuum introduction 

VACUUM INTRODUCTION

Next sequence is run if following condition is met -
EVAP pressure Saturated within 12 minutes

5. Purge VSV stuck closed check 

PURGE VSV STUCK CLOSED

Next sequence is run if following condition is met -
EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more

6. Atmospheric pressure 

ATMOSPHERIC PRESSURE

EVAP monitor is complete if the following condition is met -
Atmospheric pressure difference between sequence 1 and 6 Within 0.3 kPa (2.25 mmHg)