  1. Start the engine.
  2. Turn the audio system off.
  3. While pressing the "MEMORY 4" button, turn the volume control dial clockwise or counterclockwise for 30 clicks or more. (When the self-diagnosis mode is started, a short beep will be heard.)
    • Shifting from current screen to previous screen is performed by pressing "BACK" button.
      Fig 1: Turning Volume Control Dial Clockwise Or Counterclockwise
      G04757237
  4. The initial self-diagnosis screen will be shown, and items "Self-Diagnosis (DCU)""Self-Diagnosis (NAVI)""Confirmation/Adjustment" and "CAN DIAG SUPPORT MONITOR" will become selective.
    Fig 2: Display Initial Self-Diagnosis Screen
    G04757238
  5. Perform self-diagnosis by selecting the "Self-Diagnosis".
    • Self-diagnosis subdivision screen will be shown and the operation enters the self-diagnosis mode.
    • A bar graph shown below the self-diagnosis subdivision screen indicates progress of the diagnosis.
      Fig 3: Display Self-Diagnosis Subdivision Screen
      G04757239
  6. When the self-diagnosis completes, optional part confirmation screen will be shown.
    • When connection of an optional part is judged error, a screen to check if the optional part is actually fitted on the vehicle or not will be shown. When fitted, select the switch of the part on the screen and press "End". Then the "SELF DIAGNOSIS" screen will be shown.
    • When the optional part is connected normally, the switch for the part will not appear on the screen.
      Fig 4: Display Optional Part Confirmation Screen
      G04757240
  7. On the "SELF DIAGNOSIS" screen, each unit name will be colored according to the diagnosis result, as follows.

    Green : Not malfunctioning. 

    Yellow : Cannot be judged by self-diagnosis results. 

    Red : Unit is malfunctioning. 

    Gray : Diagnosis has not been done. 

    • If several malfunctions are present in a unit, color of its switch on the screen will be either red, yellow, or gray, determined by the malfunction of the highest priority.
      Fig 5: Display Self Diagnosis Screen
      G04757241
  8. Select a switch on the "SELF DIAGNOSIS" screen and comments for the diagnosis results will be shown.
    • When the switch is green, the following comment will be shown. "Self-diagnosis was successful. Further diagnosis and adjustments are recommended. Follow the "confirmation/adjustment" menu or refer to the service article."
    • When the switch is yellow, the following comment will be shown. "Connection to the following unit is abnormal. See the service article for further details".
    • When the switch is red, the following comment will be shown. "DCU is abnormal".
      Fig 6: Display Comment
      G04757242