Control When Handle Pulled When Operating Enable Conditions Not Yet Met
WARNING: This page is about a different car, the 2006 Nissan Quest. However, it is still accessible from the selected car via links, so may be relevant.
CONTROL WHEN HANDLE PULLED WHEN OPERATING ENABLE CONDITIONS NOT YET MET
| Items | Operation condition | Not met case | Control |
|---|---|---|---|
| Main switch | ON | OFF | Manual mode (after finishing open/close operation if active) |
| A/T selector lever P position | P position | Other than P position | Power close operation only |
| Voltage drop | 11V or more | 11 > V > 9 | Power operation will continue but will not begin from full close position |
| 9 > V > reset voltage | Power operation will stop and warning chime will sound | ||
| Reset voltage > V | No power function available | ||
| Handle switch | Normal | Error | No operation |