System Description: Inputs
Power is supplied at all times
- to BCM terminal 70
- through 50A fusible link (letter f, located in the fuse and fusible link box).
Power is supplied at all times
- to key switch terminal 3 and
- to BCM terminal 57
- through 10A fuse [No. 21, located in the fuse block (J/B)].
When the key switch is ON (ignition key is inserted in key cylinder), power is supplied
- through key switch terminal 4
- to BCM terminal 37.
When the front door switch LH is ON (door is OPEN), ground is supplied
- to BCM terminal 47.
- through front door switch LH terminal 2
- to front door switch LH case ground.
When the front door switch RH is ON (door is OPEN), ground is supplied
- to BCM terminal 12
- through front door switch RH terminal 2
- to front door switch RH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
- to BCM terminal 13
- through rear door switch RH terminal 1
- to rear door switch RH case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
- to BCM terminal 48
- through rear door switch LH terminal 1
- to rear door switch LH case ground.
Keyfob signal is inputted to BCM.
The remote keyless entry system controls operation of the
- power door lock
- trunk lid opener
- interior lamp
- panic alarm
- hazard and horn reminder
- keyless power window down (open)