CONSULT-II Reference Value in Data Monitor Mode
Specification data are reference values.
CONSULT-II REFERENCE VALUE
| MONITOR ITEM | CONDITION | SPECIFICATION | |
|---|---|---|---|
| BRAKE SW1 (ASCD brake switch) |
|
Brake pedal: Fully released (A/T) Clutch pedal and brake pedal: Fully released (M/T) |
ON |
| Brake pedal: Slightly depressed (A/T) Clutch pedal and/or brake pedal: Slightly depressed (M/T) |
OFF | ||
| BRAKE SW2 (Stop lamp switch) |
|
Brake pedal: Fully released | OFF |
| Brake pedal: Slightly depressed | ON | ||