Component Inspection
- CHECK TUMBLE CONTROL VALVE
With CONSULT-III
- Turn ignition switch OFF.
- Remove intake manifold adapter. Refer to "REMOVAL AND INSTALLATION ".
- Visually check the valve for damage and check if foreign matter is caught between the valve and the housing.
- Connect tumble control valve actuator harness connector.
- Turn ignition switch ON.
- Perform "TUMBLE CONTROL VALVE" in "ACTIVE TEST" mode with CONSULT-III.
- Touch "ON/OFF" and check that the valve opens and closes.
Without CONSULT-III
- Turn ignition switch OFF.
- Remove intake manifold adapter. Refer to "REMOVAL AND INSTALLATION ".
- Visually check the valve for damage and check if foreign matter is caught between the valve and the housing.
- Supply tumble control valve actuator terminals with battery voltage within 2 seconds and check operation.TERMINALS REFERENCE
Tumble control valve actuator Operation Terminal (+) (-) 4 5 Open 5 4 Close CAUTION: Do not apply 12V DC continuously for 30 seconds or more. Doing so may result in damage to the coil in tumble control valve motor.
Is the inspection result normal?
YES: INSPECTION END
NO: Replace intake manifold adaptor.