| P2004 |
Tumble control valve stuck |
The target angle of tumble control valve controlled by ECM and the input signal from tumble control valve position sensor is not in the normal range. |
- Harness or connectors (Tumble control valve motor circuit is open or shorted.)
(Tumble control valve position sensor circuit is open or shorted.)
(Accelerator pedal position sensor 2 circuit is shorted.)
[Crankshaft position sensor (POS) circuit is shorted.]
(EVAP control system pressure sensor circuit is shorted.)
(Refrigerant pressure sensor circuit is shorted.)
- Tumble control valve actuator (Tumble control valve motor)
(Tumble control valve position sensor)
- Accelerator pedal position sensor (APP sensor 2)
- Crankshaft position sensor (POS)
- EVAP control system pressure sensor
- Refrigerant pressure sensor
|