LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2009 >> Maxima S >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - DTCS P0451 To P1217 >> P0452 EVAP Control System Pressure Sensor >> Diagnosis Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnosis Procedure

  1. CHECK GROUND CONNECTION
    1. Turn ignition switch OFF.
    2. Check ground connection E9. Refer to Ground Inspection in "CIRCUIT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 2.

    NO: Repair or replace ground connection.

  2. CHECK CONNECTOR
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check that water is not inside connectors.

    Is the inspection result normal? 

    YES: GO TO 3.

    NO: Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.
    VOLTAGE SPECIFICATION

    EVAP control system pressure sensor Ground Voltage (V)
    Connector Terminal
    B41 3 Ground Approx. 5
    Fig 1: Checking Voltage Between EVAP Control System Pressure Sensor Harness Connector And Ground
    G05869878Courtesy of NISSAN MOTOR CO., U.S.A.

    Is the inspection result normal? 

    YES: GO TO 10.

    NO: GO TO 4.

  4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
    CONTINUITY CHART

    EVAP control system pressure sensor ECM Continuity
    Connector Terminal Connector Terminal
    B41 3 E10 91 Existed

    Is the inspection result normal? 

    YES: GO TO 6.

    NO: GO TO 5.

  5. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B29, E29
    • Harness for open or short between EVAP control system pressure sensor and ECM

    : Repair open circuit.

  6. CHECK SENSOR POWER SUPPLY CIRCUIT

    Check harness for short to power and short to ground, between the following terminals.

    ECM SPECIFICATION

    ECM Sensor
    Connector Terminal Name Connector Terminal
    F13 72 Refrigerant pressure sensor E219 1
    76 CKP sensor (POS) F30 1
    E10 87 APP sensor E40 6
    91 EVAP control system pressure sensor B41 3

    Is the inspection result normal? 

    YES: GO TO 7.

    NO: Repair short to ground or short to power in harness or connectors.

  7. CHECK COMPONENTS

    Check the following.

    Is the inspection result normal? 

    YES: GO TO 8.

    NO: Replace malfunctioning components.

  8. CHECK APP SENSOR

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 15.

    NO: GO TO 9.

  9. REPLACE ACCELERATOR PEDAL ASSEMBLY
    1. Replace accelerator pedal assembly.
    2. Refer to "SPECIAL REPAIR REQUIREMENT ".

    : INSPECTION END

  10. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      CONTINUITY CHART

      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 1 E10 96 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal? 

    YES: GO TO 12.

    NO: GO TO 11.

  11. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B10, E29
    • Harness for open or short between EVAP control system pressure sensor and ECM

    : Repair open circuit, short to ground or short to power in harness or connectors.

  12. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      CONTINUITY CHART

      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 2 E10 86 Existed
    2. Also check harness for short to ground and short to power.

    Is the inspection result normal? 

    YES: GO TO 14.

    NO: GO TO 13.

  13. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B10, E29
    • Harness for open or short between EVAP control system pressure sensor and ECM

    : Repair open circuit, short to ground or short to power in harness or connectors.

  14. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 15.

    NO: Replace EVAP control system pressure sensor.

  15. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

    : INSPECTION END