Check Fuel Level Sensor Unit and Fuel Pump
Check resistance between fuel level sensor unit and fuel pump connector terminals 2 and 5.
RESISTANCE SPECIFICATION CHART
| Terminals | Float position mm (in) | Resistance value Ω (Approx.) | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 2 | 5 | (1) | Empty | 15 (0.59) | 81 | ||||
| (2) | Full | 193 (7.6) | 5 | ||||||
|
|||||||||