Component Function Check
- PERFORM COMPONENT FUNCTION CHECK
Without CONSULT-III
- Lift up drive wheels.
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF, wait at least 10 seconds.
- Start engine and wait at least 70 seconds.
- Set voltmeter probes to ECM harness connector terminals.CONNECTOR TERMINAL REFERENCE
ECM ECM Connector Terminal Connector Terminal E16 86 (EVAP control system pressure sensor signal) E16 96 (Sensor ground) - Check EVAP control system pressure sensor value at idle speed and note it.
- Establish and maintain the following conditions for at least 1 minute.AIR CONDITIONER SWITCH REFERENCE
Air conditioner switch ON Headlamp switch ON Rear window defogger switch ON Engine speed Approx. 3,000 rpm Selector lever Any position other than P, N or R - Verify that EVAP control system pressure sensor value stays 0.1V less than the value at idle speed (measured at step 6) for at least 1 second.
Is the inspection result normal?
YES: INSPECTION END
NO: Go to "DIAGNOSIS PROCEDURE ".