INSTRUMENT CENTER : Component Function Check
- CHECK INSIDE KEY ANTENNA INPUT SIGNAL
With CONSULT-III
- Check "ANTENNA" in "Active Test" mode with CONSULT-III.
- Touch "ROOM ANT 2".
- When Intelligent Key is in inside key antenna (instrument center) detection area, LED (on Intelligent Key) blinks.
TEST ITEM REFERENCETest Item Inside Antenna ANTENNA :ROOM ANT 2 Inside key antenna (instrument center) Is the inspection result normal?
YES: Inside key antenna (instrument center) is OK.
NO: Refer to "INSTRUMENT CENTER : DIAGNOSIS PROCEDURE ".