Operation Procedure
- After turning OFF the ignition switch, connect CONSULT-III and the CONSULT-III CONVERTER to the data link connector.CAUTION: If CONSULT-III is used with no connection of CONSULT-III CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carries out CAN communication.
- Touch "START (NISSAN BASED VHCL)""ABS""DATA MONITOR" in order on the CONSULT-III screen. If "ABS" is not indicated, go to
"CONSULT-III DATA LINK CONNECTOR (DLC) CIRCUIT
".CAUTION: When "START (NISSAN BASED VHCL)" is touched immediately after starting the engine or turning on the ignition switch"ABS" might not be displayed in the SELECT SYSTEM screen. In this case, repeat the operation from step 2.
- Return to the SELECT MONITOR ITEM screen, and touch "ECU INPUT SIGNALS""MAIN SIGNALS" or "SELECTION FROM MENU". Refer to the following information.
- When "START" is touched, the data monitor screen is displayed.