Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E21. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK COOLING FAN MOTOR CIRCUIT
- Disconnect cooling fan motor harness connector.
- Check the continuity between IPDM E/R harness connector and cooling fan motor harness connector.TERMINAL CONTINUITY REFERENCE CHART
IPDM E/R Cooling fan motor Continuity Connector Terminal Connector Terminal E10 5 E62 1 Existed 7 2 E11 10 3 - Check the continuity between cooling fan motor harness connector and ground.TERMINAL CONTINUITY REFERENCE CHART
Cooling fan motor Ground Continuity Connector Terminal E62 4 Ground Existed - Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 4.
NG: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between cooling fan motor and IPDM E/R
- Harness for open or short between cooling fan motor and ground
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK COOLING FAN MOTOR
Refer to "COMPONENT INSPECTION ".
OK or NG
OK: GO TO 5.
NG: Replace cooling fan motor.
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
OK or NG
OK: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION "(WITH I-Key) or "REMOVAL AND INSTALLATION "(WITHOUT I-Key).
NG: Repair or replace harness or connector.