Component Inspection
- CHECK THROTTLE CONTROL MOTOR
- Turn ignition switch OFF.
- Disconnect electric throttle control actuator harness connector.
- Check the resistance between electric throttle control actuator terminals as per the following.
TERMINAL RESISTANCE CHARTTerminals Resistance 5 and 6 Approx. 1 - 15 Ω [at 25°C (77°F)] Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
- Replace electric throttle control actuator.
- Perform "SPECIAL REPAIR REQUIREMENT ".
INSPECTION END