Diagnosis Procedure

  1. CHECK GROUND CONNECTION
    1. Turn A/C switch and blower fan switch OFF.
    2. Stop engine.
    3. Turn ignition switch OFF.
    4. Check ground connection E38. Refer to "CIRCUIT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 2.

    NO: Repair or replace ground connection.

  2. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
    1. Disconnect refrigerant pressure sensor harness connector.
    2. Turn ignition switch ON.
    3. Check the voltage between refrigerant pressure sensor harness connector and ground.
    TERMINAL VOLTAGE REFERENCE CHART

    Refrigerant pressure sensor Ground Voltage
    Connector Terminal
    E49 3 Ground Approx. 5 V

    Is the inspection result normal? 

    YES: GO TO  4.

    NO: GO TO 3.

  3. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors F1, E8
    • Harness for open or short between ECM and refrigerant pressure sensor

    Repair open circuit or short to ground or short to power in harness or connectors.

  4. CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
      TERMINAL CONTINUITY REFERENCE CHART

      Refrigerant pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      E49 1 F8 48 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal? 

    YES: GO TO  6.

    NO: GO TO 5.

  5. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E8, F1
    • Harness for open or short between ECM and refrigerant pressure sensor

    Repair open circuit or short to ground or short to power in harness or connectors.

  6. CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Check the continuity between ECM harness connector and refrigerant pressure sensor harness connector.
      TERMINAL CONTINUITY REFERENCE CHART

      Refrigerant pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      E49 2 F8 41 Existed
    2. Also check harness for short to ground and short to power.

    Is the inspection result normal? 

    YES: GO TO  8.

    NO: GO TO 7.

  7. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E8, F1
    • Harness for open or short between ECM and refrigerant pressure sensor

    Repair open circuit or short to ground or short to power in harness or connectors.

  8. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

    Is the inspection result normal? 

    YES: Replace refrigerant pressure sensor.

    NO: Repair or replace.