Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES: Go to 2.
NO: Repair or replace ground connection.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES: Go to 3.
NO: Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.VOLTAGE REFERENCE CHART
EVAP control system pressure sensor Ground Voltage Connector Terminal B21 3 Ground Approx. 5 V Is the inspection result normal?
YES: Go to 10.
NO: Go to 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.CONTINUITY CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B21 3 F8 76 Existed Is the inspection result normal?
YES: Go to 6.
NO: Go to 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B4, M79
- Harness connectors M77, E105
- Harness connectors E8, F1
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
ECM CONNECTOR TERMINAL REFERENCE CHARTECM Sensor Connector Terminal Name Connector Terminal F8 69 Tumble control valve actuator F22 1 71 Battery current sensor F53 1 74 Refrigerant pressure sensor E49 3 75 CKP sensor (POS) F20 1 76 EVAP control system pressure sensor B21 3 E16 102 APP sensor E110 5 Is the inspection result normal?
YES: Go to 7.
NO: Repair short to ground or short to power in harness or connectors.
- CHECK COMPONENTS
Check the following.
- Battery current sensor (Refer to "COMPONENT INSPECTION ".)
- Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
- Refrigerant pressure sensor (Refer to "DIAGNOSIS PROCEDURE ".)
- Tumble control valve (Refer to
"COMPONENT INSPECTION
".)
Is the inspection result normal?
YES: Go to 8.
NO: Replace malfunctioning component.
- CHECK APP SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Go to 10.
NO: Go to 9.
- REPLACE ACCELERATOR PEDAL ASSEMBLY
Replace accelerator pedal assembly. Refer to "REMOVAL AND INSTALLATION ".
INSPECTION END
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.CONTINUITY CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B21 1 F8 51 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: Go to 12.
NO: Go to 11.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B4, M79
- Harness connectors M77, E105
- Harness connectors E8, F1
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.CONTINUITY CHART
EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B21 2 F8 42 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: Go to 14.
NO: Go to 13.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors B4, M79
- Harness connectors M77, E105
- Harness connectors E8, F1
- Harness for open or short between EVAP control system pressure sensor and ECM
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Go to 15.
NO: Replace EVAP control system pressure sensor. Refer to "EXPLODED VIEW ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
INSPECTION END