LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2011 >> Maxima S >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - DTCS P0451 Through P1217 >> DTC P0452: EVAP Control System Pressure Sensor >> Diagnosis Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnosis Procedure

Regarding Wiring Diagram information, refer to "WIRING DIAGRAM-ENGINE CONTROL SYSTEM- ".

  1. CHECK GROUND CONNECTION
    1. Turn ignition switch OFF.
    2. Check ground connection E9. Refer to Ground Inspection in "CIRCUIT INSPECTION ".

      Is the inspection result normal? 

      YES >> GO TO 2.

      NO >> Repair or replace ground connection.

  2. CHECK CONNECTOR
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check that water is not inside connectors.

      Is the inspection result normal? 

      YES >> GO TO 3.

      NO >> Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.
      VOLTAGE REFERENCE CHART

      EVAP control system pressure sensor Ground Voltage (V)
      Connector Terminal
      B41 3 Ground Approx. 5
      Fig 1: Checking Voltage Between EVAP Control System Pressure Sensor Harness Connector And Ground
      G04875257Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES >> GO TO  10.

      NO >> GO TO 4.

  4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      CONTINUITY CHART

      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 3 E10 91 Existed

      Is the inspection result normal? 

      YES >> GO TO  6.

      NO >> GO TO 5.

  5. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B29, E29
    • Harness for open or short between EVAP control system pressure sensor and ECM

      Repair open circuit.

  6. CHECK SENSOR POWER SUPPLY CIRCUIT

    Check harness for short to power and short to ground, between the following terminals.

    ECM CONNECTOR TERMINALS CHART

    ECM Sensor
    Connector Terminal Name Connector Terminal
    F13 72 Refrigerant pressure sensor E219 1
    76 CKP sensor (POS) F30 1
    E10 87 APP sensor E40 6
    91 EVAP control system pressure sensor B41 3

    Is the inspection result normal? 

    YES >> GO TO 7.

    NO >> Repair short to ground or short to power in harness or connectors.

  7. CHECK COMPONENTS

    Check the following.

    • Crankshaft position sensor (POS) (Refer to "COMPONENT INSPECTION ".)
    • Refrigerant pressure sensor (Refer to "DIAGNOSIS PROCEDURE ".)

      Is the inspection result normal? 

      YES >> GO TO 8.

      NO >> Replace malfunctioning components.

  8. CHECK APP SENSOR

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES >> GO TO  15.

    NO >> GO TO 9.

  9. REPLACE ACCELERATOR PEDAL ASSEMBLY
    1. Replace accelerator pedal assembly. Refer to REMOVAL AND INSTALLATION .
    2. Refer to "SPECIAL REPAIR REQUIREMENT ".

      INSPECTION END

  10. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      CONTINUITY CHART

      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 1 E10 96 Existed
    4. Also check harness for short to ground and short to power.

      Is the inspection result normal? 

      YES >> GO TO  12.

      NO >> GO TO 11.

  11. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B10, E29
    • Harness for open or short between EVAP control system pressure sensor and ECM

      Repair open circuit, short to ground or short to power in harness or connectors.

  12. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      CONTINUITY CHART

      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      B41 2 E10 86 Existed
    2. Also check harness for short to ground and short to power.

      Is the inspection result normal? 

      YES >> GO TO  14.

      NO >> GO TO 13.

  13. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B10, E29
    • Harness for open or short between EVAP control system pressure sensor and ECM

      Repair open circuit, short to ground or short to power in harness or connectors.

  14. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES >> GO TO 15.

    NO >> Replace EVAP control system pressure sensor.

  15. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

    INSPECTION END