Diagnosis Procedure

  1. CHECK GROUND CONNECTIONS
    1. Turn ignition switch OFF.
    2. Loosen and retighten ground screws on the body.

      Refer to "GROUND INSPECTION ".

      • : Vehicle front
      • Body ground (1)

      OK or NG 

      OK: GO TO 2.

      NG: Repair or replace ground connections.

      Fig 1: Location Of Body Ground
      G07140072Courtesy of NISSAN MOTOR CO., U.S.A.
  2. CHECK CONNECTOR
    1. Disconnect EVAP control system pressure sensor (1) harness connector.
      • This illustration is a view from under vehicle
      • EVAP canister (2)
      • EVAP canister vent control valve (3)
    2. Check sensor harness connector for water.

      Water should not exist  .

      Fig 2: Location Of EVAP Control System Pressure Sensor, EVAP Canister And EVAP Canister Vent Control Valve
      G07140073Courtesy of NISSAN MOTOR CO., U.S.A.

      OK or NG 

      OK: GO TO 3.

      NG: Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
    1. Turn ignition switch ON.
    2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-III or tester.

      Voltage: Approximately 5 V 

      OK or NG 

      OK: GO TO  11.

      NG: GO TO 4.

      Fig 3: Checking Voltage Between Ignition Coil Terminal 3 And Ground
      G07140074Courtesy of NISSAN MOTOR CO., U.S.A.
  4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check harness continuity between EVAP control system pressure sensor terminal 3 and ECM terminal 76. Refer to WIRING DIAGRAM .

      Continuity should exist  .

      OK or NG 

      OK: GO TO  6.

      NG: GO TO 5.

  5. CETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E3, F2
    • Harness connectors B9, E13
    • Harness for open between EVAP control system pressure sensor and ECM

    Repair open circuit.

  6. CHECK POWER SUPPLY CIRCUITS

    Check harness for short to power and short to ground between the following terminals.

    CONNECTOR TERMINALS REFERENCE CHART

    ECM terminal Sensor terminal Reference Wiring Diagram
    74 Refrigerant pressure sensor terminal 3 "WIRING DIAGRAM "
    75 Crankshaft position sensor (POS) terminal 1 "WIRING DIAGRAM "
    76 EVAP control system pressure sensor terminal 3 "WIRING DIAGRAM "
    102 APP sensor terminal 5 "WIRING DIAGRAM "

    OK or NG 

    OK: GO TO 7.

    NG: Repair short to ground or short to power in harness or connectors.

  7. CHECK REFRIGERANT PRESSURE SENSOR

    Refer to TROUBLE DIAGNOSIS .

    OK or NG 

    OK: GO TO 8.

    NG: Replace refrigerant pressure sensor. Refer to REMOVAL AND INSTALLATION FOR EXPANSION VALVE .

  8. CHECK CRANKSHAFT POSITION SENSOR (POS)

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO 9.

    NG: Replace crankshaft position sensor (POS). Refer to CYLINDER BLOCK .

  9. CHECK APP SENSOR

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO  16.

    NG: GO TO 10.

  10. REPLACE ACCELERATOR PEDAL ASSEMBLY

    Replace accelerator pedal assembly. Refer to ACCELERATOR CONTROL SYSTEM .

    INSPECTION END 

  11. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal 51. Refer to WIRING DIAGRAM .

      Continuity should exist  .

    4. Also check harness for short to ground and short to power.

      OK or NG 

      OK: GO TO  13.

      NG: GO TO 12.

  12. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E3, F2
    • Harness connectors B9, E13
    • Harness for open or short between EVAP control system pressure sensor and ECM

    Repair open circuit or short to ground or short to power in harness or connectors.

  13. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Check harness continuity between ECM terminal 42 and EVAP control system pressure sensor terminal 2. Refer to WIRING DIAGRAM .

      Continuity should exist  .

    2. Also check harness for short to ground and short to power.

      OK or NG 

      OK: GO TO  15.

      NG: GO TO 14.

  14. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E3, F2
    • Harness connectors B9, E13
    • Harness for open or short between ECM and EVAP control system pressure sensor

    Repair open circuit or short to ground or short to power in harness or connectors.

  15. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO 16.

    NG: Replace EVAP control system pressure sensor. Refer to EVAPORATIVE EMISSION SYSTEM .

  16. CHECK INTERMITTENT INCIDENT

    Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .

    INSPECTION END