Component Function Check
- PERFORM COMPONENT FUNCTION CHECK
Without CONSULT-III
- Lift up drive wheels.
- Start engine and warm it up to normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and wait at least 70 seconds.
- Set voltmeter probes to ECM harness connector and ground.TERMINAL CONNECTOR REFERENCE CHART
ECM Ground Connector Terminal F11 42 (EVAP control system pressure sensor signal) Ground - Check EVAP control system pressure sensor value at idle speed and note it.
- Establish and maintain the following conditions for at least 1 minute.
Courtesy of NISSAN MOTOR CO., U.S.A.
AIR CONDITIONER SWITCH REFERENCE CHARTAir conditioner switch ON Headlamp switch ON Rear window defogger switch ON Engine speed Approx. 3, 000 RPM Selector lever Any position other than P, N or R - Verify that EVAP control system pressure sensor value stays 0.1 V less than the value at idle speed (measured at step 6 for at least 1 second.
Is the inspection result normal?
YES: INSPECTION END
NO: Go to "DIAGNOSIS PROCEDURE ".