Diagnosis Procedure
- CHECK OUTPUT 1 - 5 CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect BCM and combination switch connectors.
- Check continuity between BCM harness connector and combination switch harness connector.
System BCM Combination switch Continuity Connector Terminal Connector Terminal OUTPUT 1 M68 36 M27 11 Existed OUTPUT 2 35 9 OUTPUT 3 34 7 OUTPUT 4 33 10 OUTPUT 5 32 13 Does continuity exist?
YES >> GO TO 2.
NO >> Repair harnesses or connectors.
- CHECK OUTPUT 1 - 5 CIRCUIT FOR SHORT
Check for continuity between BCM harness connector and ground.
System BCM Ground Continuity Connector Terminal OUTPUT 1 M68 36 Not existed OUTPUT 2 35 OUTPUT 3 34 OUTPUT 4 33 OUTPUT 5 32 Does continuity exist?
YES >> Repair harnesses or connectors.
NO >> GO TO 3.
- CHECK BCM OUTPUT VOLTAGE
- Connect BCM connector.
- Check voltage between BCM harness connector and ground.
System Terminals Voltage (Approx.) (+) (-) BCM Ground Connector Terminal OUTPUT 1 M68 36
7.0 - 8.0 VOUTPUT 2 35 OUTPUT 3 34 OUTPUT 4 33 OUTPUT 5 32 Is the measurement value normal?
YES >> Replace combination switch.
NO >> Replace BCM. Refer to "REMOVAL AND INSTALLATION ".