Component Function Check
- PERFORM COMPONENT FUNCTION CHECK
- Turn ignition switch ON.
- Check the voltage between ECM harness connector and ground under the following conditions.
ECM Ground Condition Voltage Connector Terminal F7 14 (PNP signal) Ground Selector lever P or N (CVT)
Neutral (M/T)Approx. 0 V Except above Battery voltage Is the inspection result normal?
YES >> INSPECTION END