Run the Sensor Input Display Mode
WARNING: This page is about a different car, the 2013 Acura MDX, 2012 Acura MDX, 2011 Acura MDX, and 2010 Acura MDX. However, it is still accessible from the selected car via links, so may be relevant.
- Turn the ignition switch to LOCK (0).
- Press and hold both the AUTO and RECIRCULATION CONTROL buttons, then start the engine.
- After the engine starts, release both buttons. The display panel control unit will flash the sensor number and then the value for that sensor. Record the value displayed.
- To advance to the next sensor, press the REAR WINDOW DEFOGGER/POWER MIRROR DEFOGGER button.NOTE:
- The sensor values will be displayed in degrees Celsius (°C) or an alphanumeric code. Use the chart to convert the value to degrees Fahrenheit (°F).
- If the sensor value displays "Er", this indicates there is an open or short in the circuit or sensor. Check for DTCs using the HDS, or refer to checking DTCs by DTC indication.
- If necessary, compare the sensor input display to a known-good vehicle under the same test conditions.
- If the sensor displayed value is out of the normal range, refer to the sensor test or substitute a known-good sensor, and recheck.
Sensor Item Displayed Value 0 In-car temperature °C 1 Outside air temperature °C 2 Engine coolant temperature °C 3 Solar radiation sensor value: dark = 00, flashlight = 04, cloudy = 10, sunny = 65 kcal/m2 .h 4 Front evaporator outlet air temperature °C 5 Driver's and passenger's air mix opening (low value indicates cooler air distribution, higher value indicates warmer air distribution) % of opening 6 Vent temperature air out (TAO) °C 7 Vehicle speed (vehicle must be driven to display speed) km/h 8 A/C pressure kPa 9 Rear air mix opening % of opening A Rear vent temperature air out (TAO) °C b Rear evaporator outlet air temperature °C C Humidity sensor value %rh d Fog margin °C E Solar radiation azimuth (with navigation) 10° F Solar radiation angle of elevation (with navigation) 10° CELSIUS TO FAHRENHEIT CONVERSION TABLE°C °F 0 32 1 34 2 36 3 37 4 39 5 41 6 43 7 45 8 46 9 48 10 50 11 52 12 54 13 55 14 57 15 59 16 61 17 63 18 64 19 66 20 68 21 70 22 72 23 73 24 75 25 77 26 79 27 81 28 82 29 84 30 86 31 88 32 90 33 91 34 93 35 95 36 97 37 99 38 100 39 102 40 104 41 106 42 108 43 109 44 111 45 113 46 115 47 117 48 118 49 120 50 122 51 124 52 126 53 127 54 128 55 131 56 133 57 135 58 136 59 139 60 140 61 142 62 144 63 145 64 147 65 149 66 151 67 152 68 154 69 158 70 158 71 160 72 162 73 163 74 165 75 167 76 169 77 170 78 172 79 174 80 176 81 178 82 180 83 181 84 183 85 185 86 187 87 188 88 190 89 192 90 194 91 196 92 198 93 199 94 201 95 203 96 205 97 207 98 208 99 210 ALPHANUMERIC CONVERSION TABLEDisplay Reading (Alphanumeric) °C °F % A1 thru A9 -1 thru -9 30 thru 16 -1 thru -9 B0 thru B9 -10 thru -19 14 thru -2 -10 thru -19 CO thru C9 -20 thru -29 -4 thru -20 -20 thru -29 DO thru D9 -30 thru -39 -22 thru -38 -30 thru -39 E0 thru E9 -40 thru -49 -40 thru -56 -40 thru -49 F0 thru F9 -- -- + 100 thru +109 - To cancel the sensor input display mode, press the AUTO button or turn the ignition switch to LOCK (0).