Work Support Mode
WORK ITEM
| WORK ITEM | CONDITION | USAGE |
|---|---|---|
| SAVE DATA FOR CPU REPLACE | In this mode, the data saved in VCM is stored in CONSULT. | When VCM is replaced. |
| WRITE DATA AFTER REPLACE CPU | In this mode, write data stored by "SAVE DATA FOR CPU REPLACE" in work support mode to VCM. | When VCM is replaced. |
| BATTERY GRADUAL CAP LOSS DATA CLEAR | Li-ion Battery deterioration data stored in VCM is cleared. | Always perform after Li-ion Battery controller is replaced as new one. |
| HV BATT J/B DATA CLEAR | System Main Relay cutoff count stored in VCM is cleared. | Always perform after Li-ion Battery Junction Box is replaced as new one. |
| WRITE VIN DATA | VIN is registered in VCM. | When registering VIN in VCM. |