LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2012 >> Leaf SL >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Electric Converters and Controllers >> EV Control System >> System Description >> System >> Li-Ion Battery Charge Control >> LI-ION BATTERY CHARGE CONTROL: Quick Charge Control >> Basic Control
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Basic Control

When the quick charge connector is connected to the quick charge port and the start switch of quick charger is pressed, the on-board charger transmits an EV system activation request signal to VCM. VCM then activates the F/S relay, M/C relay, and F/S CHG relay.

Next, VCM determines the target charge power based on the Li-ion battery chargeable power signal received from the Li-ion battery controller and the on-board charger chargeable power signal received from the onboard charger. VCM then sends the maximum charge power signal to the on-board charger.

The on-board charger converts the Maximum charge power signal to a charge current request signal and transmits it to the quick charger.

Simultaneously, the on-board charger activates the normal charge relay and the quick charge relay, and VCM activates system main relay 1 and system main relay 2. Consequently, the quick charge starts.

When the charge amount reaches the prescribed amount and VCM receives the Li-ion battery charge completion signal from the Li-ion battery controller, VCM stops the charging.

NOTE:
  • Even if the Li-ion battery remaining energy does not reach the predetermined level, VCM may stop the charge control after a certain period of time.
  • When the Li-ion battery temperature reaches 60°C (140°F) or higher, VCM temporarily stops quick charging and enters standby status.