CONSULT Reference Value in Data Monitor Mode
Specification data are reference values.
SPECIFICATION DATA
| Monitor item | Condition | Specification | |
|---|---|---|---|
| A/F SEN1 (B1) |
|
Maintaining engine speed at 2, 000 rpm | Fluctuates around 2.2 V |
| A/F SEN1 DIAG1 (B1) | DTC P015A and P015B self-diagnosis is incomplete. | INCMP | |
| DTC P015A and P015B self-diagnosis is complete. | CMPLT | ||
| A/F SEN1 DIAG2 (B1) | DTC P014C and P014D self-diagnosis is incomplete. | INCMP | |
| DTC P014C and P014D self-diagnosis is complete. | CMPLT | ||
| A/F SEN1 DIAG3 (B1) | The vehicle condition is not within the diagnosis range of DTC P014C, P014D, P015A or P015B. | ABSNT | |
| The vehicle condition is within the diagnosis range of DTC P014C, P014D, P015A or P015B. | PRSNT | ||