Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK DTC OF TCM
Check DTC in Self Diagnostic Result mode of TCM using CONSULT.
Is DTC detected?
YES
Perform the trouble diagnosis related to the detected DTC. Refer to DTC INDEX .
NO
GO TO STEP 2 .
- CHECK FUSE
- Turn power switch OFF.
- Check that the following fuse in IPDM E/R is not blown.
Signal name Fuse No. Ignition power supply 46 (10 A)
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Replace the blown fuse after repairing the cause of blowing.
- CHECK TRANSMISSION RANGE SWITCH POWER SUPPLY
- Disconnect transmission range switch connector.
- Turn ignition switch ON.
- Check voltage between transmission range switch harness connector and ground.
(+) (-) Voltage (V)
(Approx.)Transmission range switch Connector Terminal F26 7 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
GO TO STEP 4 .
- CHECK TRANSMISSION RANGE SWITCH POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Check continuity between transmission range switch harness connector and IPDM E/R harness connector.
Transmission range switch IPDM E/R Continuity Connector Terminal Connector Terminal F26 7 E43 14 Yes
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK BCM INPUT SIGNAL
- Turn ignition switch OFF.
- Reconnect transmission range switch connector.
- Turn ignition switch ON.
- Check voltage between BCM harness connector and ground.
(+) (-) Condition Voltage (V)
(Approx.)BCM Connector Terminal M83 69 Ground Selector lever P or N position Battery voltage Other than above 0
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
GO TO STEP 6 .
- CHECK BCM INPUT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect transmission range switch connector.
- Disconnect BCM connector.
- Check continuity between transmission range switch harness connector and BCM harness connector.
Transmission range switch BCM Continuity Connector Terminal Connector Terminal F26 10 M83 69 Yes - Check continuity between transmission range switch harness connector and ground.
Transmission range switch Ground Continuity Connector Terminal F26 10 No
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace harness.
- CHECK TRANSMISSION RANGE SWITCH
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Replace transmission range switch.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Inspection End.
- REPLACE BCM
- Replace BCM. Refer to REMOVAL AND INSTALLATION .
- Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
Inspection End.