Wiper Intermittent Dial Position Setting
BCM judges the wiper intermittent dial 1 - 7 by the status of INT VOLUME 1, 2, and 3 switches.
| Wiper intermittent dial position |
Switch status |
| INT VOLUME 1 |
INT VOLUME 2 |
INT VOLUME 3 |
| 1 |
ON |
ON |
ON |
| 2 |
ON |
ON |
OFF |
| 3 |
ON |
OFF |
OFF |
| 4 |
OFF |
OFF |
OFF |
| 5 |
OFF |
OFF |
ON |
| 6 |
OFF |
ON |
ON |
| 7 |
OFF |
ON |
OFF |