Encoder Circuit Check
- CHECK ENCODER OPERATION
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch connector D7 and ground with oscilloscope.
Signal name Terminals Signal (Reference value) (+) (-) Main power window and door lock/unlock switch connector Terminal Encoder signal 1 D7 13 Ground Refer to following signal Encoder signal 2 9 Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: GO TO 2.
- CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
- Turn ignition switch ON.
- Check voltage between front power window motor LH connector D9 and ground.
Terminal Voltage (Approx.) (+) (-) Front power window motor LH connector Terminal D9 2 Ground 10 Is the measurement value within the specification?
YES: GO TO 4.
NO: GO TO 3.
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch and front power window motor LH.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 5 D9 2 Yes - Check continuity between main power window and door lock/unlock switch connector D7 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D7 14 No Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace the harness or connectors.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect front power window motor LH.
- Check continuity between front power window motor LH connector D9 and ground.
Front power window motor LH connector Terminal Ground Continuity D9 4 Yes Is the inspection result normal?
YES: GO TO 6.
NO: GO TO 5.
- CHECK HARNESS CONTINUITY 2
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 5 D9 4 Yes Is the inspection result normal?
YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace the harness or connectors.
- CHECK HARNESS CONTINUITY 3
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector Terminal Front power window motor LH connector Terminal Continuity D7 13 D9 5 Yes 9 6 - Check continuity between main power window and door lock/unlock switch connector D7 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D7 13 No 9 Is the inspection result normal?
YES: Replace front power window motor LH. Refer to "REMOVAL AND INSTALLATION - FRONT REGULATOR ". After that, refer to "WORK PROCEDURE ".
NO: Repair or replace the harness or connectors.