Component Inspection (TP Sensor)
- CHECK THROTTLE POSITION SENSOR
- Turn ignition switch OFF.
- Reconnect all harness connectors disconnected.
- Perform "THROTTLE VALVE CLOSED POSITION LEARNING ". Refer to "WORK PROCEDURE ".
- Turn ignition switch ON.
- Set selector lever to D (CVT) or 1st (M/T) position.
- Check the voltage between ECM harness connector terminals as per the following conditions.
ECM Condition Voltage Connector + - Terminal F25 77 78 Accelerator pedal Fully released Less than 4.75 V Fully depressed More than 0.36 V 79 Fully released More than 0.36 V Fully depressed Less than 4.75 V Is the inspection result normal?
YES: INSPECTION END
NO: Replace electric throttle control actuator. Refer to "REMOVAL AND INSTALLATION ".