Inlet Port Memory Function (Rec): Description
- If the ignition switch is turned to the OFF position while the REC (
) switch is set to ON (recirculation), "Perform the memory" or "Do not perform the memory" of the REC (
) switch ON (recirculation) condition can be selected.
- If "Perform the memory" was set, the REC (
) switch will be ON (recirculation) when turning the ignition switch to the ON position again.
- If "Do not perform the memory" was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.