Diagnosis Procedure

  1. DETECT MALFUNCTIONING ITEMS

    What is malfunction item?

    ECO mode switch illumination does not turn ON 

    GO TO STEP 2  .

    ECO mode indicator does not turn ON 

    GO TO STEP 7  .

  2. CHECK ECO MODE SWITCH ILLUMINATION POWER SUPPLY (PART 1)

    1. Turn OFF the headlamp.
    2. Turn ignition switch OFF.
    3. Disconnect ECO mode switch harness connector.
    4. Turn ignition switch ON.
    5. Turn ON the headlamp.
    6. Check the voltage between ECO mode switch harness connector terminals.
      ECO mode switch Voltage
      (Approx.)
      Connector + -
      Terminal
      M1 1 4 12 V

    Is the inspection result normal?

    YES 

    GO TO STEP 3  .

    NO 

    GO TO STEP 4  .

  3. CHECK INTERMITTENT INCIDENT

    Refer to INTERMITTENT INCIDENT .

    Is the inspection result normal?

    YES 

    Replace ECO mode switch. Refer to REMOVAL AND INSTALLATION .

    NO 

    Replace the fuse after repair the applicable circuit.

  4. CHECK ECO MODE SWITCH ILLUMINATION POWER SUPPLY (PART 2)

    Check the voltage between ECO mode switch harness connector and ground.

    + - Voltage
    (Approx.)
    ECO mode switch
    Connector Terminal
    M1 1 Ground 12 V

    Is the inspection result normal?

    YES 

    GO TO STEP 6  .

    NO 

    GO TO STEP 5  .

  5. CHECK CIRCUIT BETWEEN COMBINATION METER AND ECO MODE SWITCH

    1. Disconnect combination meter connector M77.
    2. Check the continuity between combination meter harness connector terminal and ECO mode switch harness connector terminal.
      Combination meter ECO mode switch Continuity
      Connector Terminal Connector Terminal
      M77 43 M1 1 Existed
    3. Also check harness for short to ground.

    Is the inspection result normal?

    YES 

    GO TO STEP 11  .

    NO 

    Repair or replace malfunctioning parts.

  6. CHECK GROUND CIRCUIT

    1. Turn OFF the headlamp.
    2. Turn ignition switch OFF.
    3. Check continuity between ECO mode switch harness connector terminal and ground.
      ECO mode switch - Continuity
      Connector Terminal
      M1 4 Ground Existed

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Repair or replace malfunctioning parts.

  7. CHECK ECO MODE SWITCH CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect ECO mode switch connector.
    3. Turn ignition switch ON.
    4. Check voltage between ECO mode switch harness connector terminals.
      ECO mode switch Voltage
      (Approx.)
      Connector + -
      Terminal
      M1 6 8 10 V

    Is the inspection result normal?

    YES 

    GO TO STEP 12  .

    NO 

    GO TO STEP 8  .

  8. CHECK GROUND CIRCUIT

    1. Turn ignition switch OFF.
    2. Check the continuity between ECO mode switch harness connector and ground.
      ECO mode switch - Continuity
      Connector Terminal
      M1 8 Ground Existed

    Is the inspection result normal?

    YES 

    GO TO STEP 9  .

    NO 

    Repair or replace malfunctioning parts.

  9. CHECK CIRCUIT BETWEEN COMBINATION METER AND ECO MODE SWITCH (PART 1)

    1. Disconnect combination meter harness connector M76.
    2. Check continuity between combination meter harness connector terminal and ECO mode switch harness connector terminal.
      Combination meter ECO mode switch Continuity
      Connector Terminal Connector Terminal
      M76 9 M1 6 Existed

    Is the inspection result normal?

    YES 

    GO TO STEP 10  .

    NO 

    Repair or replace malfunctioning parts.

  10. CHECK CIRCUIT BETWEEN COMBINATION METER AND ECO MODE SWITCH (PART 2)

    Check continuity between combination meter harness connector terminal and ground.

    Combination meter - Continuity
    Connector Terminal
    M76 9 Ground Not existed

    Is the inspection result normal?

    YES 

    GO TO STEP 11  .

    NO 

    Repair or replace malfunctioning parts.

  11. CHECK COMBINATION METER INPUT/OUTPUT SIGNAL

    1. Connect all of disconnected connectors.
    2. Check input/output signal of combination meter. Refer to REFERENCE VALUE .

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Replace combination meter. Refer to REMOVAL AND INSTALLATION .

  12. CHECK ECO MODE SWITCH

    Check ECO mode switch. Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    Check intermittent incident. Refer to INTERMITTENT INCIDENT .

    NO 

    Replace ECO mode switch. Refer to REMOVAL AND INSTALLATION .