Diagnostic Test
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Turn ignition switch OFF.
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
+ - Voltage
(Approx.)EVAP control system pressure sensor Connector Terminal B47 3 Ground 5 V
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
+ - Continuity EVAP control system pressure sensor ECM Connector Terminal Connector Terminal B47 3 E16 113 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
+ - Continuity EVAP control system pressure sensor ECM Connector Terminal Connector Terminal B47 1 E16 124 Existed - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
+ - Continuity EVAP control system pressure sensor ECM Connector Terminal Connector Terminal B47 2 E16 114 Existed - Also check harness for short to ground and to power.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace error-detected parts.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check the EVAP control system pressure sensor. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace EVAP control system pressure sensor. Refer to REMOVAL AND INSTALLATION .