Diagnostic Test
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in CIRCUIT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace ground connection.
- CHECK VVEL CONTROL MODULE GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect VVEL control module harness connector.
- Check the continuity between VVEL control module harness connector and ground.
VVEL control module Ground Continuity Connector Terminal E15 14 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair open circuit, short to power in harness connectors.
- CHECK VVEL CONTROL MODULE POWER SUPPLY CIRCUIT-I
- Reconnect VVEL control module harness connector.
- Turn ignition switch ON.
- Check the voltage between VVEL control module harness connector and ground.
VVEL control module Voltage Connector + - Terminal Terminal E15 8 14 After turning ignition switch OFF, battery voltage will exist for a few seconds, then drop to approximately 0 V.
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
GO TO STEP 4 .
- CHECK VVEL CONTROL MODULE POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF and wait at least 10 seconds.
- Disconnect VVEL control module harness connector.
- Disconnect IPDM E/R harness connector.
- Check the continuity between VVEL control module harness connector and IPDM E/R harness connector.
VVEL control module IPDM E/R Continuity Connector Terminal Connector Terminal E15 8 E7 49 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Is the inspection result normal?
YES
Replace IPDM E/R.
NO
Repair open circuit, short to ground or short to power in harness or connectors.