Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK ENCODER OPERATION
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch connector D7 terminal 3 and ground with oscilloscope.
Main power window and door lock/unlock switch Ground Signal
(Reference value)Connector Terminal D7 3 -
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 2
- CHECK ENCODER SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch and front power window motor LH connectors.
- Check continuity between main power window and door lock/unlock switch connector D7 terminal 3 and front power window motor LH connector D9 terminal 5.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D7 3 D9 5 Yes - Check continuity between main power window and door lock/unlock switch connector D7 terminal 3 and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 3 - No
Is the inspection result normal?
YES
GO TO STEP 3
NO
Repair or replace harness.
- CHECK ENCODER POWER
- Connect main power window and door lock/unlock switch connector.
- Turn ignition switch ON.
- Check voltage between front power window motor LH connector D9 terminal 2 and ground.
Front power window motor LH Ground Voltage
(approx.)Connector Terminal D9 2 - 10V
Is the inspection result normal?
YES
GO TO STEP 5
NO
GO TO STEP 4
- CHECK ENCODER POWER CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 terminal 4 and front power window motor LH connector D9 terminal 2.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D7 4 D9 2 Yes - Check continuity between main power window and door lock/unlock switch connector D7 terminal 4 and ground.
Main power window and door lock/unlock switch Ground Continuity Connector Terminal D7 4 - No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK ENCODER GROUND
- Turn ignition switch OFF.
- Check continuity between front power window motor LH connector D9 terminal 4 and ground.
Front power window motor LH Ground Continuity Connector Terminal D9 4 - Yes
Is the inspection result normal?
YES
Replace front power window motor LH. Refer to REMOVAL AND INSTALLATION .
NO