Diagnosis Procedure
- CHECK CONTINUITY HORIZONTAL SYNCHRONIZING (HP) SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect front display unit connector and AV control unit connector.
- Check continuity between front display unit harness connector and AV control unit harness connector.
Front display unit AV control unit Continuity Connector Terminal Connector Terminal M156 8 M184 38 Existed - Check continuity between front display unit harness connector and ground.
Front display unit Ground Continuity Connector Terminal M156 8 Not existed
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair harness or connector.
- CHECK HORIZONTAL SYNCHRONIZING (HP) SIGNAL
- Connect front display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between front display unit harness connector and ground.
Probe Standard Reference value (+) (-) Front display unit Connector Terminal Connector Terminal M156 8 M156 1 Waveform of 1.0 V - 5.5 V is output.
Is the inspection result normal?
YES
Replace AV control unit. Refer to REMOVAL AND INSTALLATION .
NO
Replace front display unit. Refer to REMOVAL AND INSTALLATION .