Diagnosis Procedure - Encoder Circuit Check
- CHECK ENCODER OPERATION
- Turn ignition switch ON.
- Check signal between main power window and door lock/unlock switch connector D7 and ground with oscilloscope.
Terminals
Signal
(Reference value)
(+)
(-)
Main power window and door lock/unlock switch connector
Terminal
D7
4
Ground
Refer to following signal
5
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
GO TO 2.
- CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
- Turn ignition switch ON.
- Check voltage between front power window motor LH connector D9 and ground.
Terminal
Voltage
(Approx.)
(+)
(-)
Front power window motor LH connector
Terminal
D9
2
Ground
10
Is the measurement value within the specification?
YES
GO TO 4.
NO
GO TO 3.
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch and front power window motor LH.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector
Terminal
Front power window motor LH connector
Terminal
Continuity
D7
14
D9
2
Yes
- Check continuity between main power window and door lock/unlock switch connector D7 and ground.
Main power window and door lock/unlock switch connector
Terminal
Ground
Continuity
D7
14
No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation . After that, refer to Special Repair Requirement .
NO
Repair or replace the harness or connectors.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect front power window motor LH.
- Check continuity between front power window motor LH connector D9 and ground.
Front power window motor LH connector
Terminal
Ground
Continuity
D9
4
Yes
Is the inspection result normal?
YES
GO TO 6.
NO
GO TO 5.
- CHECK HARNESS CONTINUITY 2
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector
Terminal
Front power window motor LH connector
Terminal
Continuity
D7
12
D9
4
Yes
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation . After that, refer to Special Repair Requirement .
NO
Repair or replace the harness or connectors.
- CHECK HARNESS CONTINUITY 3
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D7 and front power window motor LH connector D9.
Main power window and door lock/unlock switch connector
Terminal
Front power window motor LH connector
Terminal
Continuity
D7
5
D9
5
Yes
4
6
- Check continuity between main power window and door lock/unlock switch connector D7 and ground.
Main power window and door lock/unlock switch connector
Terminal
Ground
Continuity
D7
5
No
4
Is the inspection result normal?
YES
Replace front power window motor LH. Refer to Removal and Installation - Front Regulator . After that, refer to Special Repair Requirement .
NO
Repair or replace the harness or connectors.