Diagnosis Procedure
- PERFORM INITIALIZATION
- Perform initialization of BCM and registration of all mechanical keys using CONSULT.
For initialization and registration procedures, refer to CONSULT Immobilizer mode and follow the on-screen instructions.
- Start the engine.
Does the engine start?
YES
Inspection End.
NO
GO TO 2.
- Perform initialization of BCM and registration of all mechanical keys using CONSULT.
- CHECK DONGLE UNIT CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector and dongle unit connector.
- Check continuity between BCM harness connector and dongle unit harness connector.
BCM
Dongle unit
Continuity
Connector
Terminal
Connector
Terminal
M21
24
M39
1
Yes
- Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M21
24
No
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness.
- CHECK DONGLE UNIT GROUND CIRCUIT
Check continuity between dongle unit harness connector and ground.
Dongle unit
Ground
Continuity
Connector
Terminal
M39
4
Yes
Is the inspection result normal?
YES
Replace dongle unit.
NO
Repair or replace harness.