LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2019 >> 370Z Base, 2D Convertible >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (Diagnostics) (2 Of 2) >> Component/Circuit Diagnosis >> Ho2S2 Heater >> Component Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Component Inspection

  1. CHECK HEATED OXYGEN SENSOR 2 HEATER 
    1. Turn ignition switch OFF.
    2. Disconnect heated oxygen sensor 2 harness connector.
    3. Check resistance between HO2S2 terminals as follows.

      Terminal

      Resistance (Ohm)

      2 and 3

      3.4 - 4.4 [at 25 deg. C (77 deg. F)]

      1 and 2, 3, 4

      INF.

      (Continuity should not exist)

      4 and 1, 2, 3

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    GO TO 2.

  2. REPLACE HEATED OXYGEN SENSOR 2 

    Replace malfunctioning heated oxygen sensor 2.

    CAUTION:
    • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
    • Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved Anti-seize Lubricant (commercial service tool).

    INSPECTION END