Component Inspection
- CHECK ECO MODE SWITCH
Check continuity between ECO mode switch connector terminals.
ECO mode switch
Condition
Continuity
Terminal
6 - 8
ECO mode switch is depressed.
Existed
ECO mode switch is released.
Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace ECO mode switch. Refer to Removal and Installation .