Physical Values
|
Terminal No. (Wire color) |
Description |
Condition |
Value (Approx.) |
|||
|
Signal name |
Input/ Output |
|||||
|
+ |
- |
|||||
|
2 (L) |
Ground |
Input 5 signal |
Input |
Combination switch |
OFF |
0 V |
|
TURN RH |
1.0 V |
|||||
|
HEADLAMP 1 |
||||||
|
HI BEAM |
||||||
|
TAIL LAMP |
||||||
|
3 (GR) |
Ground |
Input 4 signal |
Input |
Combination switch |
OFF |
0 V |
|
TURN LH |
1.0 V |
|||||
|
PASSING |
||||||
|
HEADLAMP 2 |
||||||
|
FR FOG |
||||||
|
4 (BR) |
Ground |
Input 3 signal |
Input |
Combination switch |
OFF |
0 V |
|
FR WIPER LOW |
1.0 V |
|||||
|
FR WIPER INT (any intermittent position) |
||||||
|
5 (BG) |
Ground |
Input 2 signal |
Input |
Combination switch |
OFF |
0 V |
|
FR WASHER |
1.0 V |
|||||
|
Wiper intermittent dial 1 |
||||||
|
Wiper intermittent dial 5 |
||||||
|
Wiper intermittent dial 6 |
||||||
|
6 (W) |
Ground |
Input 1 signal |
Input |
Combination switch |
OFF |
0 V |
|
FR WIPER HI |
1.0 V |
|||||
|
Wiper intermittent dial 1 |
||||||
|
Wiper intermittent dial 2 |
||||||
|
Wiper intermittent dial 3 |
||||||
|
Wiper intermittent dial 6 |
||||||
|
Wiper intermittent dial 7 |
||||||
|
7 (LA/L) |
Ground |
Key cylinder unlock sw signal |
Input |
Key cylinder switch |
N position |
7.0 - 8.0 V |
|
UNLOCK position |
0 V |
|||||
|
8 (LA/V) |
Ground |
Key cylinder lock sw signal |
Input |
Key cylinder switch |
N position |
7.0 - 8.0 V |
|
LOCK position |
0 V |
|||||
|
9 (R) |
Ground |
Brake sw signal |
Input |
Stop lamp switch |
OFF (brake pedal released) |
0 V |
|
ON (brake pedal depressed) |
Battery voltage |
|||||
|
10 (W) |
Ground |
Rear defogger sw signal |
Input |
Rear window defogger switch |
OFF |
Battery voltage |
|
ON |
0 V |
|||||
|
11 (L) |
Ground |
ACC switch signal |
Input |
Ignition switch |
OFF |
0 V |
|
ACC or ON |
Battery voltage |
|||||
|
12 (GR) |
Ground |
Central door lock sw signal |
Input |
Door lock and unlock switch |
N position |
1.0 - 1.5 V |
|
LOCK position |
0 V |
|||||
|
13 (BR) |
Ground |
Central door unlock sw signal |
Input |
Door lock and unlock switch |
N position |
1.0 - 1.5 V |
|
UNLOCK position |
0 V |
|||||
|
14 (SB) |
Ground |
Optical sensor |
Input |
Ignition switch ON |
Daylight |
5 V |
|
Night |
0 V |
|||||
|
16 (BG) |
- |
MR output |
- |
- |
- |
- |
|
17 (Y) |
Ground |
Sensor power supply |
Output |
Ignition switch |
OFF |
0 V |
|
ON |
5.0 V |
|||||
|
18 (V) |
Ground |
Keyless gnd signal |
Input |
Ignition switch ON |
0 V |
|
|
19 (BR) |
Ground |
Keyless tuner power supply |
Input |
Ignition switch OFF |
Key inserted into ignition key cylinder |
0 V |
|
Key removed from ignition key cylinder (Any door open) |
5 V |
|||||
|
Key removed from ignition key cylinder (Any door closed) |
||||||
|
20 (LG) |
Ground |
Keyless tuner signal |
Input |
Ignition switch OFF |
Key inserted into ignition key cylinder |
0 V |
|
Waiting |
||||||
|
Signal receiving |
||||||
|
21 (P) |
Ground |
Immobilizer one way communication (clock) signal |
Input/Output |
While waiting |
Turn ignition switch ON. |
Turn ignition switch ON: Pointer of tester should move. |
|
23 (Y) |
Ground |
Security indicator output signal |
Output |
Security indicator |
ON |
0 V |
|
Blinking (Ignition switch OFF) |
11.3 V |
|||||
|
OFF |
Battery voltage |
|||||
|
24 (SB) |
Ground |
Audio/dongle link (serial) signal |
Input/Output |
Ignition switch OFF. |
5 V |
|
|
25 (LG) |
Ground |
Immobilizer two way communication signal |
Input/Output |
While waiting |
Turn ignition switch ON. |
Turn ignition switch ON: Pointer of tester should move. |
|
27 (Y) |
Ground |
Air con sw signal |
Input |
A/C and fan ON switch |
OFF |
Battery voltage |
|
ON |
0 V |
|||||
|
28 (LG) |
Ground |
Blower fan sw signal |
Input |
Fan switch |
OFF |
0 V |
|
I, II, III or IIII |
7.0 - 8.0 V |
|||||
|
29 (SB) |
Ground |
Hazard sw signal |
Input |
Hazard switch |
OFF |
Battery voltage |
|
ON |
0 - 1.5 V |
|||||
|
30 (L) |
Ground |
Trunk lid opener switch |
Input |
Trunk lid opener switch |
Depressed |
0 V |
|
Released |
1.0 - 1.5 V |
|||||
|
32 (LG) |
Ground |
Output 5 signal |
Output |
Combination switch |
OFF |
7.0 - 8.0 V |
|
FR FOG |
1.2 V |
|||||
|
Wiper intermittent dial 1 |
||||||
|
Wiper intermittent dial 2 |
||||||
|
Wiper intermittent dial 6 |
||||||
|
Wiper intermittent dial 7 |
||||||
|
33 (Y) |
Ground |
Output 4 signal |
Output |
Combination switch |
OFF |
7.0 - 8.0 V |
|
TAIL LAMP |
1.2 V |
|||||
|
Wiper intermittent dial 1 |
||||||
|
Wiper intermittent dial 5 |
||||||
|
Wiper intermittent dial 6 |
||||||
|
34 (V) |
Ground |
Output 3 signal |
Output |
Combination switch |
OFF |
7.0 - 8.0 V |
|
HEADLAMP 2 |
1.2 V |
|||||
|
HI BEAM |
||||||
|
Wiper intermittent dial 1 |
||||||
|
Wiper intermittent dial 2 |
||||||
|
Wiper intermittent dial 3 |
||||||
|
35 (R) |
Ground |
Output 2 signal |
Output |
Combination switch |
OFF |
7.0 - 8.0 V |
|
FR WIPER HI |
1.2 V |
|||||
|
FR WIPER INT (any intermittent position) |
||||||
|
PASSING |
||||||
|
HEADLAMP 1 |
||||||
|
36 (SB) |
Ground |
Output 1 signal |
Output |
Combination switch |
OFF |
7.0 - 8.0 V |
|
FR WASHER |
1.2 V |
|||||
|
FR WIPER LOW |
||||||
|
TURN LH |
||||||
|
TURN RH |
||||||
|
37 (GR) |
Ground |
Key sw signal |
Input |
Ignition switch |
Ignition key inserted into ignition key cylinder |
Battery voltage |
|
Ignition key removed from ignition key cylinder |
0 V |
|||||
|
38 (R) |
Ground |
Ign sw signal |
Input |
Ignition switch |
OFF or ACC |
0 V |
|
ON or START |
Battery voltage |
|||||
|
39 (L) |
Ground |
CAN-H signal |
Input/Output |
- |
- |
|
|
40 (P) |
Ground |
CAN-L signal |
Input/Output |
- |
- |
|
|
41 (LG) |
Ground |
Flasher output (LEFT) signal |
Output |
Ignition switch ON |
Turn signal switch OFF |
0 V |
|
Turn signal switch LH |
6.5 V (Turn signal lamp turn on: 9 - 16 V) |
|||||
|
42 (BG) |
Ground |
Flasher output (RIGHT) signal |
Output |
Ignition switch ON |
Turn signal switch OFF |
0 V |
|
Turn signal switch RH |
6.5 V (Turn signal lamp turn on: 9 - 16 V) |
|||||
|
45 (R) |
Ground |
Door sw (AS) signal |
Input |
Front door switch RH |
OFF (front door RH closed) |
7.0 - 8.0 V |
|
ON (front door RH open) |
0 V |
|||||
|
46 (Y) |
Ground |
Door sw (DR) signal |
Input |
Front door switch LH |
OFF (front door LH closed) |
7.0 - 8.0 V |
|
ON (front door LH open) |
0 V |
|||||
|
47 (GR) |
Ground |
Door sw (RL) signal |
Input |
Rear door switch LH |
OFF (rear door LH closed) |
7.0 - 8.0 V |
|
ON (rear door LH open) |
0 V |
|||||
|
48 (P) |
Ground |
Door sw (RR) signal |
Input |
Rear door switch RH |
OFF (rear door RH closed) |
7.0 - 8.0 V |
|
ON (rear door RH open) |
0 V |
|||||
|
50 (LG) |
Ground |
Trunk room lamp output signal |
Output |
Trunk lid |
Closed (trunk room lamp OFF) |
Battery voltage |
|
Open (trunk room lamp ON) |
0 - 1 V |
|||||
|
51 (V) |
Ground |
Trunk lid sw signal |
Input |
Trunk lid switch |
OFF (Trunk lid closed) |
7.0 - 8.0 V |
|
ON (Trunk lid open) |
0 V |
|||||
|
55 (GR) |
Ground |
Trunk open output |
Output |
Trunk opener request switch released |
Trunk lid actuator idle |
0 V |
|
Trunk opener request switch depressed |
Trunk lid actuator activated |
Battery voltage |
||||
|
60 (BR) |
Ground |
Room lamp output signal |
Output |
Interior room lamp or map lamp |
OFF |
Battery voltage |
|
ON |
Battery voltage |
|||||
|
DOOR |
0 - 1 V |
|||||
|
62 (P) |
Ground |
Battery saver output signal |
Output |
Interior room lamp battery saver activated |
0 V |
|
|
Interior room lamp battery saver not activated |
Battery voltage |
|||||
|
63 (BG) |
Ground |
Battery (FUSE) |
Input |
Ignition switch OFF |
Battery voltage |
|
|
64 (SB) |
Ground |
Door unlock output (DR) signal |
Output |
Front door lock actuator LH |
Actuated to UNLOCK position |
Battery voltage |
|
Other than actuated to UNLOCK position |
0 V |
|||||
|
65 (B) |
Ground |
Ground |
Output |
Ignition switch ON |
0 V |
|
|
66 (O) |
Ground |
Door lock output signal |
Output |
All door lock actuators |
Actuated to LOCK position |
Battery voltage |
|
Other than actuated to LOCK position |
0 V |
|||||
|
67 (SB) |
Ground |
Door unlock output (AS, RR, RL) signal |
Output |
Front door lock actuator RH, rear door lock actuator RH and rear door lock actuator LH |
Actuated to UNLOCK position |
Battery voltage |
|
Other than actuated to UNLOCK position |
0 V |
|||||
|
68 (L) |
Ground |
Power window power supply (RAP) signal |
Output |
Ignition switch ON |
Battery voltage |
|
|
69 (G) |
Ground |
Power window power supply (BATT) |
Output |
Push-button ignition switch |
OFF |
Battery voltage |
|
70 (Y) |
Ground |
Battery (F/L) |
Input |
Ignition switch OFF |
Battery voltage |
|