CONSULT Function (BCM - INT LAMP)
DATA MONITOR
|
Monitor Item [Unit] |
Description |
|
IGN ON SW [On/Off] |
Indicates condition of ignition switch ON position. |
|
KEY ON SW [On/Off] |
Indicates condition of key switch. |
|
DOOR SW-DR [On/Off] |
Indicates condition of front door switch LH. |
|
DOOR SW-AS [On/Off] |
Indicates condition of front door switch RH. |
|
DOOR SW-RR [On/Off] |
Indicates condition of rear door switch RH. |
|
DOOR SW-RL [On/Off] |
Indicates condition of rear door switch LH. |
|
CDL LOCK SW [On/Off] |
Indicates condition of lock signal from door lock and unlock switch. |
|
CDL UNLOCK SW [On/Off] |
Indicates condition of unlock signal from door lock and unlock switch. |
|
KEYLESS LOCK [On/Off] |
Indicates condition of lock signal from keyfob. |
|
KEYLESS UNLOCK [On/Off] |
Indicates condition of unlock signal from keyfob. |
|
TRNK/HAT MNTR [On/Off] |
Indicates condition of trunk lid switch. |
|
KEY CYL LK-SW [On/Off] |
Indicates condition of lock signal from door key cylinder switch. |
|
KEY CYL UN-SW [On/Off] |
Indicates condition of unlock signal from door key cylinder switch. |
|
ACC SW [On/Off] |
Indicates condition of ignition switch ACC position. |
ACTIVE TEST
|
Test Item |
Description |
|
INT LAMP |
This test is able to check interior room lamp operation [On/Off]. |
WORK SUPPORT
|
Support Item |
Setting |
Description |
|
|
SET I/L D-UNLCK INTCON |
On* |
Interior room lamp timer function ON. |
|
|
Off |
Interior room lamp timer function OFF. |
||
|
ROOM LAMP TIMER SET |
MODE 4 |
30 sec. |
Sets the interior room lamp ON time. (Timer operating time). |
|
MODE 3* |
15 sec. |
||
|
MODE 2 |
7.5 sec. |
||
|
MODE 1 |
OFF |
||
|
ROOM LAMP ON TIME SET |
MODE7 |
0 sec. |
Sets the interior room lamp gradual brightening time. |
|
MODE6 |
5 sec. |
||
|
MODE5 |
4 sec. |
||
|
MODE4 |
3 sec. |
||
|
MODE3 |
2 sec. |
||
|
MODE2* |
1 sec. |
||
|
MODE1 |
0.5 sec. |
||
|
ROOM LAMP OFF TIME SET |
MODE7 |
0 sec. |
Sets the interior room lamp gradual dimming time. |
|
MODE6 |
5 sec. |
||
|
MODE5 |
4 sec. |
||
|
MODE4 |
3 sec. |
||
|
MODE3 |
2 sec. |
||
|
MODE2* |
1 sec. |
||
|
MODE1 |
0.5 sec. |
||
|
R LAMP TIMER LOGIC SET |
MODE 2 |
Interior room lamp timer activates with all doors. |
|
|
MODE 1* |
Interior room lamp timer activates with the driver door only. |
||
* : Initial setting