Diagnosis Procedure
Regarding Wiring Diagram information, refer to the appropriate Wiring Diagram .
- CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector and ground.
(+)
(-)
Voltage (V)
Combination meter
Connector
Terminal
M82
27
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 2 .
NO
Check 10 A fuse [No. 8, located in the fuse block (J/B)].
NO
Check harness for open or short between combination meter and fuse.
- CHECK SECURITY INDICATOR LAMP SIGNAL
- Connect combination meter connector.
- Disconnect BCM connector.
- Check voltage between BCM harness connector and ground.
(+)
(-)
Voltage (V)
BCM
Connector
Terminal
M18
23
Ground
Battery voltage
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
GO TO 3 .
- CHECK SECURITY INDICATOR LAMP CIRCUIT
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and BCM harness connector.
Combination meter
BCM
Continuity
Connector
Terminal
Connector
Terminal
M82
18
M18
23
Yes
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M82
18
No
Is the inspection result normal?
YES
Replace combination meter. Refer to Removal and Installation .
NO
Repair or replace harness.