Model*

A002TJ1791ZX

Manufacturer

Mitsubishi

Nominal rating

12V - 110A

Ground polarity

Negative

Minimum revolution under no-load

1, 000 rpm

Hot output current (When 13.5 V is applied)

More than 95A/2, 500 rpm

More than 116A/5, 000 rpm

Regulated output voltage

14.1 - 14.7V @20°C (68°F)

Adjustment range of power generation voltage variable control

11.4 - 15.6V